MYCKRO마이크로
Field testingMachine Vision Software

MYCKRO Vision

If you can program a robot, you can set up vision.

Machine vision software for robot guidance and simple inspection — designed in the language of robot engineers, not vision specialists.

Modes (Locator · Inspector · Reader)
3Modes (Locator · Inspector · Reader)
Calibration wizard
6-stepCalibration wizard
Robot offset output
X · Y · RRobot offset output
Protocols (Modbus TCP · ASCII)
2Protocols (Modbus TCP · ASCII)
01MODES

3 modes

Each job uses one mode. Only the menus that mode needs appear on screen, so first-time users know exactly what to set up.

Locator

MODE 01

Find position

Finds a taught shape and reports the part's position and angle in robot coordinates. Built for robot picking and assembly offsets.

  • Shape-matching detection of position, rotation and scale
  • Calibration converts image coordinates to robot coordinates (mm)
  • Multi-learning builds models robust to lighting and surface variation
  • Multi Match — finds several parts and sorts them in your chosen order
  • Score and X/Y/R limits, output sign and fine scale adjustment
OUTPUTOK/NG + X · Y · R offsets → PLC · robot

Inspector

MODE 02

Inspect

Checks that bolts, taps, holes and other features are present at set locations. Just register the items to check — no master model needed.

  • Independent shape model per item — inspect many spots in one shot
  • Search margin (50% by default) tolerates small position shifts
  • Pass threshold (%) per item
  • Exclusion masks remove unwanted edges at registration
  • Saves PASS/NG history with the image at the time of judgment
OUTPUTPASS/NG result → PLC · robot

Reader

MODE 03

Barcode · QR reading

Reads barcodes and QR codes in defined regions, then displays and logs the values. No model registration needed.

  • Reads multiple code regions in one image
  • Just draw a region — no model registration
  • Failed reads are shown as the industry-standard ‘NO READ’
  • Logs item, value and result to a read-history file
  • Sends read values to PLC · robot over ASCII (coming soon)
OUTPUTRead value + PASS/NG → PLC · robot (ASCII, coming soon)
02SCREENS

Screens

PASS — finds the position and angle of a rotated part and outputs offsets (X · Y · R)
PASS — finds the position and angle of a rotated part and outputs offsets (X · Y · R)
FAIL — when the part is covered and the score falls below the threshold, the coordinate is not trusted and NG is returned
FAIL — when the part is covered and the score falls below the threshold, the coordinate is not trusted and NG is returned
Calibration wizard — jog the robot as guided and capture; scale, camera rotation and orthogonality are calculated automatically
Calibration wizard — jog the robot as guided and capture; scale, camera rotation and orthogonality are calculated automatically
Setup — verify detection right after registering a model
Setup — verify detection right after registering a model
Setup — model region, search region and mask editing
Setup — model region, search region and mask editing
Advanced settings — limits, Multi Match, rotation and scale search ranges
Advanced settings — limits, Multi Match, rotation and scale search ranges
03PROBLEM

The problem on the floor

  1. 01

    Conventional machine vision is expensive to deploy and needs a vision specialist for setup.

  2. 02

    Calibrating the camera to the robot coordinate frame is a heavy lift for field engineers.

  3. 03

    PLC and robot communication differs by vendor, which drags out commissioning.

04HOW IT WORKS

Robot integration flow

  1. STEP 01

    Select job

    The robot or PLC sends a job number to load the inspection job.

  2. STEP 02

    Confirm job

    Vision replies with the loaded job number so the match can be checked.

  3. STEP 03

    Trigger

    When the robot reaches the capture position, it requests an inspection.

  4. STEP 04

    Result · offsets

    When done, Vision replies with the result code and offsets (X, Y, R) in one message.

  5. STEP 05

    Corrected move

    OK: move with the offsets. NG: retry, then alarm — keeping the robot program simple.

05FEATURES

Key features

6-step calibration wizard

Computes the transform automatically, even with a tilted camera. Multi-point measurement and least-squares manual correction are also available.

Modbus TCP / ASCII

Exchanges job select, trigger, Busy/Pass/NG and result codes with PLCs and robots. The register map is configurable on site.

Runtime / Setup separation

Operator and setup screens are separate, and Setup is password-protected. Operators see results; only engineers change settings.

Multi-learning

Learns only the edges that appear consistently across several shots, producing models that hold up to lighting and surface variation.

Multi Match + Sort

Finds every part in the search region at once and hands them over in the order that is easiest for the robot to pick.

Communication setup wizard

Guides you step by step: choose protocol → connection test → live signal check → save the settings sheet. Vendor presets included.

Numbered jobs

The PLC selects jobs by number. Export, import and duplicate make moving jobs between lines simple.

Inspection history log

Stores, searches and filters PASS/NG history. Saving to a shared folder supports quality traceability.

Fail-safe judgment

If image capture fails, it never judges from a previous image — it returns an error code immediately, so the robot never moves to a bad coordinate.

06INTERFACE

PLC · robot communication

ASCII TCP · EXAMPLE
ROBOT → JOB:5
VISION ← 1,5  // Job 5 loaded
ROBOT → TRIG
VISION ← 1,-12.34,15.77,178.90  // OK · X, Y, R offsets
ROBOT → TRIG
VISION ← 2,0.00,0.00,0.00  // NG · zero coordinates
ROBOT → RESET
VISION ← 1  // State reset
RESULT CODE
1OK
2NG
3No camera response
4BUSY (inspecting)
5Job not found
6Job not loaded
7Model not registered
8Command error

ASCII and Modbus TCP share the same result codes. Full details are in the communication manual.

07SPECIFICATION

Specifications

PlatformWindows · .NET (WPF)
Image EngineOpenCV-based
ModesLocator / Inspector / Reader
InterfaceModbus TCP · ASCII TCP
Verified PLCLS XEC series (Modbus server)
CameraUSB3 global shutter · GigE planned
08APPLICATIONS

Applications

  • Robot picking offsets
  • Part presence inspection
  • Barcode / QR traceability
  • Pre-assembly pose check

Talk to us about MYCKRO Vision

Request a demo, a field trial or a spec consultation.

NEXT PRODUCT

Telay →

Wireless Terminal Block